Manually Setting Bus ID on an EmpirBus™ Membrane Panel 8BP

To manually set the Bus ID

  1. Power the unit on

  2. Hold button 7 for 20 seconds

  3. Press button 8 3 times and the base address will begin flashing

  4. Use buttons 5 and 6 to adjust the base address

  5. Save the new base address by holding button 7 for another 20 seconds

The base address is expressed by the total sum of the lit buttons. If buttons 1 and 3 are lit, the base address will be 5. If buttons 2, 5, and 6 are lit, the base address will be 50.

  • Indication on button 1 is 0 or 1, 0 when off and 1 when lit

  • Indication on button 2 is 0 or 2, 0 when off and 2 when lit

  • Indication on button 3 is 0 or 4, 0 when off and 4 when lit

  • Indication on button 4 is 0 or 8, 0 when off and 8 when lit

  • Indication on button 5 is 0 or 16, 0 when off and 16 when lit

  • Indication on button 6 is 0 or 32, 0 when off and 32 when lit

  • Indication on button 7 is 0 or 64, 0 when off and 64 when lit

  • Indication on button 8 is 0 or 128, 0 when off and 128 when lit