Select your product to confirm this information applies to you
Editing Gun Properties on a Garmin Wearable with Applied Ballistics
To edit the gun properties on a compatible Garmin wearable with Applied Ballistics follow the steps below. You can also create a profile using the Applied Ballistics Quantum™ app on your compatible smartphone or tablet - see the Related for more information.
Edit Applied Ballistics Page Values
From the Applied Ballistics app press
.
Select Profile.
Select Gun Properties.
Select the option you want to edit:
Muzzle Velocity - the speed of the bullet as it leaves the muzzle.
Zero Range - the range at which the rifle was zeroed.
Sight Height - the distance from the center axis of the rifle barrel to the center axis of the scope.
Zero Height - An optional modification to impact elevation at zero range. This is often used when adding a suppressor or using a subsonic load.
For example, if you add a suppressor and your bullet impacts the target 1 inch higher than expected, your Zero Height is 1 inch. You must set this to zero when you remove the suppressor.
Zero Offset - an optional modification to impact windage at zero range. This is often used when adding a suppressor or using a subsonic load.
For example, if you add a suppressor and your bullet impacts the target 1 inch to the left of the expected impact, your ZERO OFFSET is -1 inch. You want to remember to set this to zero when you remove the suppressor.
SSF - Elevation - a linear multiplier that accounts for vertical scaling. Not all rifle scopes track perfectly, so the ballistics solution requires a correction to scale according to a particular rifle scope.
For example, if a turret is moved 10 mil but the impact is 9 mil, the sight scale is 0.9.
SSF - Windage - a linear multiplier that accounts for horizontal scaling. Not all rifle scopes track perfectly, so the ballistics solution requires a correction to scale according to a particular scope.
For example, if a turret is moved 10 mil but the impact is 9 mil, the sight scale is 0.9.
Twist Rate - the distance it takes for the rifling of your barrel to make one full rotation. Rifle twist is often provided by the gun or barrel manufacturer.
Calibrate Muzzle Velocity
Calibrating the muzzle velocity provides a more accurate solution in the supersonic range for your specific firearm.
From the Applied Ballistics app press
.
Select Profile.
Select Gun Properties.
Select Calibrate Muzzle Velocity.
Select an option:
Select Range to edit the range - the distance from the muzzle to the target.
Select True Drop to edit the drop distance - the actual distance the bullet falls while in flight to the target, displayed in milliradians (mil) or minute of angle (MOA).
Select the check mark.
TIP: You should enter a value as close as possible to the range suggested in the shooting solution. This is the range where the bullet slows to Mach 1.2 and begins to enter the transonic range.
Calibrate Drop Scale Factor
Garmin recommends you calibrate the muzzle velocity prior to the drop scale factor.
Calibrating the drop scale factor provides a more accurate solution at or beyond the transonic range for your specific firearm.
From the Applied Ballistics app press
.
Select Profile
Select Gun Properties
Select Calibrate DSF.
Select an option:
Select Range to edit the range - the range from which you are shooting.
Select True Drop to edit the drop distance - the actual distance the bullet falls when fired at a specific range, displayed in milliradians (mil) or minute of angle (MOA).
Select the check mark.
NOTE: For Instinct® 2X Solar - Tactical Edition, select BACK.
TIP: This range should be within 90% of the recommended range suggested in the shooting solution. Values that are less than 80% of the recommended range will not provide a valid adjustment.
Viewing the Drop Scale Factor Table
The drop scale factor table is populated after you calibrate the drop scale factor. If necessary, you can reset the table values to zero
From the Applied Ballistics app press
.
Select Profile.
Select Gun Properties.
Select View DSF Table.
If necessary, hold MENU and select Clear DSF Table.
The table values reset to zero.