PRODUCTS AFFECTED:
G1000 NXi-equipped Embraer EMB-500 Phenom 100 aircraft with system software version 3643.00 or 3643.01 installed under STC SA01933WI are affected.
G1000 NXi-equipped Embraer EMB-505 Phenom 300 aircraft with system software version 3643.01 installed under STC SA01933WI are also affected.
CERTIFICATION AUTHORIZATION:
STC SA01933WI
COMPLIANCE:
MANDATORY: Compliance with the STC service bulletin is mandatory at the next 100-hour/annual inspection, not to exceed 6 months.
PURPOSE:
This Service Bulletin announces the approval of G1000 NXi System Software Version 3643.03 in Embraer EMB-500 Phenom 100 and EMB-505 Phenom 300 aircraft.
G1000 NXi System Software Version 3643.03 provides the following enhancements:
- Phenom 100
- Corrects the EDM (Emergency Descent Mode) annunciation color from red to green
- Enables the CVR (Cockpit Voice Recorder) erase function
- Enables the CVR failure indication
- Enables the FDR (Flight Data Recorder) failure indication
- Enables the cabin altitude high driven automatic thrust reserve inhibit
- Phenom 300
- Corrects issue with the VENTRAL RUD FAIL advisory CAS message displaying after engine start
- Enables the CVR (Cockpit Voice Recorder) erase function
- Enables the CVR failure indication
- Enables the FDR 1 (Flight Data Recorder) failure indication
- Enables the FDR 2 (Flight Data Recorder) failure indication
- Enables the cabin altitude high driven automatic thrust reserve inhibit