Select your product to confirm this information applies to you

How Does the OnDeck Hub Prevent a 12V or 24V Battery Power Source From Over Discharging?

The OnDeck™ Hub switches to running on its internal battery when it is not in a full-power state and the voltage of the external power input drops to < 11.9V for a 12V system or < 23.8V for a 24V system.

The system type is determined by the voltage of the external power input: < 15V for a 12V system and > 18V for a 24V system.

The OnDeck Hub switches back to running from the external power input when it rises to >= 12.4V for a 12V system or >= 24.3V for a 24V system.

The internal battery lasts about 48 hours under typical use.

The OnDeck Hub when powered off can consume up to 7mA of power.