Select your product to confirm this information applies to you
Rally Series and Vector 3 Series Status LED Lights
The Rally series and Vector 3 series power meters feature status LEDs on the end of the spindle located on the inside of each crank arm. Single sided power meters will only have a status LED on the left pedal. The pedals do not flash an LED when the batteries are low in order to conserve the remainder of their life.

Error Codes
| LED Light Status | Pedal Status | Troubleshooting Tips |
| 1 red flash | The Vector or Rally system is active and working properly. | None |
| 3 green flashes every 10 seconds (Vector 3) / every 5 seconds (Rally) | The pedal is searching for the other pedal. | Confirm opposite pedal has good batteries and pedal is in working condition. |
| Alternating red and green flashes | A software update is in progress. | Wait for software update to finish installing |
| 20 green flashes | The software update was successful. The pedals found each other successfully and are up to date. | None |
| 20 red flashes | The software update failed. The left pedal could not find the right pedal or failed to update the right pedal. | Reapply software update |