Intermittent signal with a gWind Wired Transducer

The GND10 is powering the wired gWind or the WSI-box (from the N2k). However, there is a current limit to protect the GND10. The power limit is set to power the transducer or the WSI but nothing else. If there are other units connected to the Nexus Network or other transducers connected to the WSI-box, external power has to be connected to the WSI-box.


If there is too much load on the Nexus port of the GND10, the power will not be sufficient to feed the Nexus Network side. The voltage drop is 1.5V in idle and if the current increases over 30mA the voltage drop will increase.