Select your product to confirm this information applies to you
(2023) Service Advisory 23040 Rev A: TA/RA Triggered On Ground
PRODUCTS AFFECTED:
G1000 NXi-equipped Embraer EMB-500 Phenom 100 and EMB-505 Phenom 300 aircraft with system software version 3643.06 (or earlier) installed under STC SA01933WI with ACSS TCAS II and KRA 405B are affected.
ISSUE:
TA/RAs are triggered on the ground during RADALT initialization.
PILOT ACTION:
After starting the avionics, make sure TCAS is in Standby mode.
Activate TCAS when on the runway.
RESOLUTION:
The nuisance RADALT behavior will be addressed in a future software release.