Database Sync Improvements for GTN Xi, TXi, and GI 275 Avionics

As part of our continuing efforts to increase the capabilities and performance of our products, we have released software updates to improve the Database Sync functionality between the GTN™ Xi, TXi™, and GI 275 avionics units.


Improvements include:

  • A Database Sync update process that can now transfer data between units up to 10x faster, from 10 Megabits per second (Mbps) to 100 Mbps.

  • A coordinated restart of the avionics units, whereby a prompt will appear on the unit to restart all the displays that have received a database update. This will eliminate the need for power cycling the avionics for current database updates to take effect. This will also allow for power to the primary communication unit to stay functional during Database Sync transfers.

  • All warnings, with respect to databases being out-of-sync, will now appear on the primary display.  This will reduce pilot verification of database installation by centralizing database warning messages on one device.

  • These updates will become functional upon aircraft owners updating their software according to the table below:
  • Minimum Main Software Version Required for Improved Database Sync Functionality

    Device Software Version
    GI 2752.60
    GTN Xi 20.30
    TXi3.20


Avionics with certain software versions will no longer be able to perform a Database Sync update because of the previously mentioned updates. Those devices that are described in the table below can still accept updates by putting the databases directly onto their respective SD cards.  This limitation will be fixed in future GTN 6XX/7XX and GPS 175/GNC 355/GNX 375 software versions:

  • Database Sync Exclusions per STC Service Bulletin 23003 Rev B

    Device


    Unit sending data: GTN 6XX/7XX with software version 6.72 or lower

    Unit sending data: GPS 175 GPS Navigator/ GNC® 355 radio / GNX™ 375 IFR Navigator Transponder with a software version 3.12 or lower

    Unit Receiving Data: TXi with a software version 3.50 and higher

    NoNo

    Unit Receiving Data: GI 275 with a software version 2.60 or higher

    NoYes



Database Sync limitations between GTN and GTN Xi units:

  • A GTN Xi software version 20.30 or later can transfer databases to a GTN legacy software version 6.72 or lower.

  • A GTN legacy software version 6.72 or lower cannot transfer databases to a GTN Xi with a software version 20.30 or later. This will be corrected in a future software update for GTN legacy units.

  • The Main Software Version currently installed in your device on most units can be found on the same screen as your system I.D. Any software updates for your units will be available from your Garmin Dealer.